HP Array Controller Utility CLI
can be ran from the Linux CLI or as its own shell
show controller details
=> controller all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438004E11F50 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 3.52 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True
Show physical disk details for that controller
=> controller slot=0 physicaldrive all show detail Smart Array P410i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 Port: 1I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: PLX7DURE Model: HP EH0146FARWD Current Temperature (C): 23 Maximum Temperature (C): 26 PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 146 GB Rotational Speed: 15000 Firmware Revision: HPD9 Serial Number: PLX8W3NE Model: HP EH0146FARWD Current Temperature (C): 22 Maximum Temperature (C): 26 PHY Count: 2 PHY Transfer Rate: 6.0GBPS, Unknown
Add disks into an Array
controller slot=5 array A add drives=1:1-1:5 controller slot=5 array A add spares=allunassigned ctrl slot=5 logicaldrive 1 add drives=1:8 controller slot=5 modify expandpriority=low
Extend Logical Drive size
controller slot=1 logicaldrive 1 modify size=12000